Serial Port Data Logger Circuit
N1. MM Logger Website Configurer. The Configurer is our name for the tabbed dialog that appears when you click Config on the Entry Window top menu, and then choose Configure Ports, Mode Control, Audio, Other. The Configurer has many tabs with program settings influencing all aspects of the behavior of the program. Be careful in setting up items on the different tabs, to be sure that you understand that the option you are choosing is what you want. Configurer settings are remembered by the program in the N1. MM Logger. ini file, which is in the N1. MM Logger user files area. Great USB tool for 13ch signals control, monitoring as oscilloscope, data acquisition and circuit troubleshooting at 1mSecSamples period. Function key definitions, telnet clusters, call history, and country information are not saved in the. That means, for example, that function key definitions loaded or modified when you are using one database will only appear in that database. You will need to export them from that database and load them into another database before they would show up there. The N1. MM Logger. If you have not unchecked Hide extensions for known file types in Windows Explorer Options, you will not see N1. MM Logger. ini. You will see N1. MM Logger with a Type of Configuration Settings. Configurer Hardware tab. A-Beginner%E2%80%99s-data-logger-project-using-PIC12F683-microcontroller-Schematic.jpg?x49121' alt='Serial Port Data Logger Circuit' title='Serial Port Data Logger Circuit' />High Precision Digital RTDThermocouple ThermometerData Logger. Serial Port Data Logger Circuit' title='Serial Port Data Logger Circuit' />The Hardware tab is used to set up your radios, packet interfaces, telnet connections, CWPTTdigital ports and the interfaces to other devices, such as SO2. R controllers, multi purpose interfaces, and keyers, if they require serial or parallel ports. Set the values appropriate to your station. Apogee Duet Drivers Snow Leopard From Store'>Apogee Duet Drivers Snow Leopard From Store. If you do not have one of the items listed connected to a port, make sure the port selection is None and the check boxes are not checked for that port. Hardware setup options. The program supports up to 8 serial ports, each of which can be anywhere in the range COM1 COM9. LPT1 LPT3. Set up each port depending on what equipment is connected and enter the appropriate information. A more detailed explanation of each of the controls on this window follows. Port for each device that is to be connected via a COM port, the COM port number is selected in this column from a pull down list. This example screen shot shows a case in which three COM ports are being used. COM6 is used for radio control of an Elecraft K3. COM2 is being used for a Winkeyer for CW keying. COM1. 0 is connected to a TNC or terminal unit for RTTY. The radio has two receivers and the program is configured for SO2. V Single Operator, 2 VFOs with two Entry windows, one for each VFOreceiver. This list displays all of the COM ports the program was able to open. In this example, COM1, COM2, COM5 and COM1. Configurer window was opened. These ports might include real serial ports, USB to serial adapters, andor virtual serial ports created by software drivers e. Ham Router, LP Bridge, etc. COM6 also appears on the example list above, but with an asterisk beside it. The asterisk indicates that this port was previously configured at this position in the N1. MM Logger. ini file, but when the Configurer was opened, the program was unable to open the port. This could be the result of a USB to serial adapter being unplugged, or as the result of other software that had previously created a virtual serial port but that was not running at the time the Configurer was opened. If this asterisked device is left configured for COM6, after exiting the Configurer the program will issue a warning that it was unable to open the port. The function that should be provided by this port will be unavailable. This can be corrected by connecting the USB adapter or creating the software virtual port in the other software, then reopening and closing the Configurer. If a different COM port is selected from the list, the missing COM port denoted by the asterisk will disappear from the pull down list. Radio The pull down list in the box in this column can be used to select a radio that is to be interfaced with the program using this port for radio control, i. A maximum of two radios can be connected. Pstools Win7 on this page. Select None if this port is not being used for radio control. If you have only one radio connected, only one of the boxes in this column should be configured to anything other than NoneDigital Checking this box means this port is used for digital communication MMTTYMMVARIFldigi engine or TNC. This box cannot be checked if this port is used for radio control. Conversely, if this box is checked the pull down list in the Radio column is disabled. Not all ports used for digital communication are configured here check this box only if one of the following conditions is met. Use this to indicate a port that is used for a TU or TNC for RTTY. Use it to indicate a port that is used for PTT from MMVARI in digital modes. This is not necessary with the external digital engines MMTTY, 2. Tone and Fldigi, only with MMVARI. Use it to indicate a port that will be time shared between digital and non digital modes. This could be, for example, a port that is used for serial port CW keying when the operating mode is CW, and for FSK andor PTT keying when the operating mode is RTTY. The CWOther box will also be checked for such a time shared port. If the only time the port is used is in digital modes from MMTTY, 2. Tone or Fldigi, it is not necessary to check this check box simply configure the port directly within the digital engine without setting it up in the Configurer. If you control PTT from the radio control port or from a Winkeyer, do not check the Digital box for that port. If you are using a port for FSK keying with MMTTY or MMVARI via the EXTFSK or EXTFSK6. Digital box for this port. CWOther Check this box if this port is used for CW, PTT, a footswitch, a DVK or an SO2. R controller. This selection may be made in combination with a Radio or Digital selection provided the uses are compatible e. Winkeyer and radio control cannot use the same serial port, because both use serial communications, whereas keying CW on the DTR control line can be compatible with radio control on the same port if your hardware interface supports it. In addition to the serial ports, the CWOther box can also be selected for one or more parallel ports LPT123 to be used for CW or PTT keying or for other types of device control. Of course, you must specify serial or parallel port to be used. Configuring a Port for a Winkeyer To configure a port for a Winkeyer, first select a port, in the left most column of the Hardware tab. Then check the CWOther box in that same row. Set button and check the Winkeyer box in the dialog that appears Use ONLY ONE method of PTT or CW keying. Note that having multiple ports configured for CW or PTT can cause problems for example, having two methods of PTT control operating at the same time can result in the radio failing to switch to transmit, or worse, locking up in transmit at the end of a function key message. Pick one method of CW keying and one method of PTT control, check the CWOther box for the port or ports you need for them and complete the port configuration using the Set button, and make sure CWOther is not checked for ports that you are not currently using. For digital modes, do not configure PTT control from the digital engine MMTTY or Fldigi if you have PTT control operating from the main N1. MM Logger program. Details Click on the Set button in this column to open a window with a set of controls that depends on what is selected in the preceding columns Radio, Digital, Packet, CWOther. C Windows Service Socket Communication Timeout. To the right of the details column is a summary of the detailed settings.